Boilers guoconstruction


 Boilers guoconstruction

 Boilers guoconstruction
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA
I need the quotation of for Ton/KW , the fuel is , use for ,My name is , my Email is ,my phone number is , Please Send the detail information for me!

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

NHB-150 Ultra-High Efficiency Condensing Heating Boiler

high efficiency Condensing Heating Boiler. Super condensing efficiency. Dual stainless steel heat exchangers. SCH40, 2" PVC venting up to 60'. ½" Gas pipe up to 40'. TDR up to 15:1. Integrated controls. << See other models.

Get Price

Condensation inside Navien tankless water heater — Heating

Navien water heaters boilers notorious for these problems. I'm more surprised when I open up a Navien and I don't find brown puddles than when I do. 9/10 will have this going on. Don't expect any help from Navien, they won't provide any. I would encourage you to join the class action lawsuit and replace that Navien as soon as possible.

Get Price

Navien Announces New Combi-boilers and Boilers | phcppros

Apr 20, 2021 · Navien also revealed upgrades to its fire tube lines with the NFC-H fire tube combi-boilers and NFB-H fire tube boilers, including higher turndown ratios, wider BTU ranges and longer venting options. Specifically, both the NFC-H and NFB-H now offer turndown ratios up to 15:1, 2-inch venting up to 65 feet and 3-inch venting up to 150 feet.

Get Price

Navien Combi Boilers | Page 6 | DIYnot Forums

Navien Tankless Water Heater Cost for Installation for Gas

Get Price

Navien Error Code e012 - DoItYourself.com Community Forums

Nov 22, 2020 · My boiler sized properly when all four heat zones in my house run simultaneously. Unfortunately, if 3 zones or less call for heat, the system short cycles. Two zones are hydroair while the third is a two kickspace heaters with blowers and the fourth is tube-fin baseboard.

Get Price

Navien Boiler | DIYnot Forums

Nov 25, 2020 · Hello.. We have installed a new Navien Blue Flame oil boiler. We are using the Hive hub and controller to control and program the boiler. However, although we can trigger the boiler to turn on and off etc via the controller, it seems to be ignoring the schedule we have programmed into the Hive. For example, on the Hive, we scheduled the boiler

Get Price

navien outdoor temp sensor | DIY Home Improvement Forum

May 23, 2015 · The boiler uses the temperature sensor to set the aquastat target temperature. Colder outside, higher boiler target temp. Without the outdoor sensor, the boiler will default to the max (about 180f usually) anytime there is a call for heat. On spring/fall days with lower heating requirements, the boiler will tend to short cycle and efficiency

Get Price

Combi-Boilers | Eco-Friendly & Energy Efficient | Navien

Explore Navien Combi-boiler Applications. Navien Combi boilers offer endless hot water on demand for any size home, and with heat inputs up to 199,000 BTU/H, they are compatible with a variety of whole house heating applications such as finned tube and cast iron baseboards, radiant floor heating systems, fan coils, radiators, and air handlers.

Get Price

Navien NCB 240 flame loss (E012) - DoItYourself.com

Mar 01, 2017 · Boiler info: Weil-McLain WGO-4, installed when house was built late 2004. Boiler tech came over, and sure enough, we found this: [ATTACH]76859[/ATTACH] (this pic is just after wiping it clean - leaks considerably more when circulating) Crack is about 2" long, horizontal, approx 7" up from the bottom in the center section.

Get Price

Navien combi boilers | Page 3 | Plumbing Zone

Mar 23, 2012 · Actually its all over the country you can use a water heater including tankless as a heat source provided that you have a fixture draw connection (Combi use) Tankless Water Heaters are typically certified to the American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.3/CSA 4.3. and tank water heaters are certified to CSA 4.1.

Get Price

Navien Combi Boilers | Page 5 | DIYnot Forums

Where are navien boilers made? - Ask & Get Answered

Get Price

Boiler shortages | DIYnot Forums

Jul 18, 2021 · DIYnot Forums. Home Forums > General > General Discussion > Boiler shortages. Discussion in 'General Discussion' started by transam, 8 Feb 2022 at 10:30 PM. transam. Joined: 20 Nov 2009 Messages: 31,962 Thanks Received: 3,781 Location: Surrey Country: WB have suspended the manu

Get Price

Boiler shortages | DIYnot Forums

Jul 18, 2021 · DIYnot Forums. Home Forums > General > General Discussion > Boiler shortages. Discussion in 'General Discussion' started by transam, 8 Feb 2022 at 10:30 PM. transam. Joined: 20 Nov 2009 Messages: 31,962 Thanks Received: 3,781 Location: Surrey Country: WB have suspended the manu

Get Price

Navien boiler short cycling — Heating Help: The Wall

Feb 05, 2022 · The three red pumps are for Navien boiler. There's one on top left for circulating water through zones. One directly under the Navien boiler, I believe that is for pulling water from circulation to boiler. Then there's a pump on the indirect hot water inlet. The blue circulation pump in the picture is for pumping hot water across our house

Get Price

Navien combi boilers - Professional Plumbers Forum

Dec 08, 2011 · navien Even if navien does not have H stamp, (except one model), It has parameters best boilers in the world can dream on, with the price tag below the ground, it is still china (or korea)made crap, with belief that cheaper product is better because it is cheaper, and filling our houses with cheap useless crap, causing only headaches, instead of providing years …

Get Price

Boiler shortages | DIYnot Forums

Jul 18, 2021 · DIYnot Forums. Home Forums > General > General Discussion > Boiler shortages. Discussion in 'General Discussion' started by transam, 8 Feb 2022 at 10:30 PM. transam. Joined: 20 Nov 2009 Messages: 31,962 Thanks Received: 3,781 Location: Surrey Country: WB have suspended the manu

Get Price

High Pressure Boiler Answer Key Fifth Edition

Vaillant ecoFIT Pure 830 Gas Combi Boiler | Boilers Updated for 2021, our best selling gas condensing boiler. Efficient, compact, quiet and affordable, the Vitodens 100-W hydrogen ready (H2 20% blend) gas condensing boiler is the most popular solution for …

Get Price

Navien Combi boiler flush question - DoItYourself.com

Jan 05, 2022 · Boilers - Home Heating Steam and Hot Water Systems - Navien Combi boiler flush question - Hello, I am preparing to do a flush of my Navien NCB-240E combi boiler. I have it connected to a hydro air handler on the space heating closed loop side but for now I am only going to flush the domestic hot water side. In all of

Get Price

Navien Combi Boilers | Page 8 | DIYnot Forums

Aug 25, 2018 · Navien's Claim of being able to run off 15mm is only the same as other manufacturers who produce the gas tail in 15mm. They aren't saying 15mm will be enough. You need minimum WP. All modern boilers are Negative pressure. Just because the fan pulls it doesn't mean you can get away with a smaller pipe.

Get Price

Navien Boiler Problem - hvac-talk.com

Feb 01, 2013 · I have a Navien CH-240 Combi (new install) in my second home, and the domestic hot water temperature is unstable. I have the temperature set to 120*F, and when I open a faucet, the boiler ramps up, the water gets hot, but then the boiler cuts back and the water gets cooler, and this continues. The water never really gets to 120*, and the temp goes up and down and up …

Get Price

navien ch240 hot water is working but not heating the

Dec 19, 2017 · Boilers - Home Heating Steam and Hot Water Systems - navien ch240 hot water is working but not heating the house - The problem started this morning / last night. I'm still getting hot water on the DHW side but not getting any hot air from my air handler. The pipes that go to the air handler are cold to touch, I suspect

Get Price

Help with adjusting Navien Boiler / Outdoor Reset

Jan 02, 2022 · The system is a Navien NHB-80 with a Caleffi ZVR106 zone controller for the valves on the 4 space heating zones and a 40gal indirect water heater (Heat-Flo HF40). I'll attach a photo of the entire system. TL;DR - Here's a few questions on things I'd like to improve: 1.

Get Price

Viessmann HE boiler with or without indirect tank? New

Jan 29, 2022 · Long story short, I "need" to replace a 40+ year old boiler and HW heater to get the byproducts out of the chimney liner (I have a 2 family, and the liner is not sized appropriately for 2 boilers and 2 HW heaters, and chimney expert says fitting correct size is likely impossible).If I get a Viessman, do I also need new rads?

Get Price

What temp do most people set their boilers to

Dec 01, 2015 · Mar 13, 2012. #9. Most condensing boilers condense for longer when the return temp is around 55 degrees. Ideally you want to keep it condensing for longer, for energy efficiency. So the way that I always do it, when setting up a new system or balancing an existing system is: Add the differential across the flow and return onto the 55 degrees

Get Price

Navien UK Navien LCB700 Blue Flame

Oil Regular/System and Combi Boilers. Blue flame is set to replace yellow flame in oil boilers. Navien's revolutionary blue flame technology guarantees superior efficiency and ultra-low NOx emissions. Weighing only 67kg, the Navien LCB700 is lightweight, easy to handle and optimized for a simple, fast and cost-effective installation.

Get Price

Navien Tankless Water Heater Comments and questions

Jan 19, 2009 · The added value gas saved by the Navien's condensing aspect won't likely be greater than the boost you get to the overall system efficiency by increasing the duty cycle of the heating system boiler- even a lowly 83% AFUE cast-iron boiler.

Get Price

Navien boiler not heating home. - DoItYourself.com

Dec 21, 2013 · Boilers - Home Heating Steam and Hot Water Systems - Navien boiler not heating home. - I had a Navien CH 240 NG installed the other week. Still working out some issues regarding it getting dialed in. Currently running at 180 temp, Tstats set at 72, not satisfying, only reaching 68 when its real cold outside (20/25).

Get Price

Combi boilers - Viessmann vs. Navien - RedFlagDeals.com Forums

Nov 13, 2019 · Combi boilers - Viessmann vs. Navien. We are looking to replace our current combi Wall mounted boiler for our home and were debating between a Viessmann or a Navien. Any input would be great. We have a crappy HTP that the builder installed and it has been nothing but trouble. Viessmann certianly makes very high quality products.

Get Price

Massey Plumbing And Heating : auto air vent valve leaking

Oct 15, 2021 · This common problem has a few potential causes. In the cold winter months, boilers act as an important source of heat that wards off the worst of the chills, keeping families comfortable. auto air vent valve leaking in the loft | DIYnot Forums from .diynot.com This common problem has a few potential causes. Plumbing is an important part of a

Get Price

navien comi boiler ch240 ng asme — Heating Help: The Wall

navien comi boiler ch240 ng asme. During the 1st heating season my Navien operated at a pressure reading of 21.8 during a call for heat. manual shows an operating pressure between 7 and 30 psi. After I drained the unit (Oct 30, 2014)before the 2nd heating season to clean. the unit operated at the same pressure as the last season.

Get Price

Combi boilers - Viessmann vs. Navien - RedFlagDeals.com Forums

Nov 13, 2019 · Combi boilers - Viessmann vs. Navien. We are looking to replace our current combi Wall mounted boiler for our home and were debating between a Viessmann or a Navien. Any input would be great. We have a crappy HTP that the builder installed and it has been nothing but trouble. Viessmann certianly makes very high quality products.

Get Price

Navien Combi System NCB-210E - Temperature Issue | Terry

Oct 22, 2018 · I'm new to the forum and hopefully someone will be able to help me. I recently bought a new house that was converted to gas. A new Navien combi boiler was put in to replace the old furnace. I've moved in for 3 weeks, everything was fine until this past week when the temperature dropped. I have 3 zones in the house, basement, 1st floor and 2nd

Get Price

Neat: Navien tankless boiler | AnandTech Forums

May 09, 2015 · May 1, 2015. #2. Yeah, tankless condensing boilers are great. I had my garage slab set up with pex tubing for a future boiler install. I opted to run a pellet stove this year as LP prices are still out of control, but hopefully the prices drop enough to make it worthwhile. A navien was on my short list of heat sources.

Get Price

Condensing Boiler Fan Motor

Glow Worm 18 hxi Condensing Boiler fan | DIYnot Forums. 2019/9/3 · 1. Location: Cheshire. Country: Need some help from someone who is familiar with these boilers. The fan in this developed out-of-balance problems resulting in very noisy operation and vibration. This was replaced with a new fan which lasted for about 5 hours and then stopped.

Get Price

Help with return water dip switch settings (Navien NCB

Nov 30, 2021 · Water Heater Forum & Blog. Boiler Forum . Help with return water dip switch settings (Navien NCB 240e) Thread starter Dobson; Start date 21 minutes ago; Tags combi boiler navien I have a brand new Navien NCB 240e that so far has given me nothing but problems. However, I'm slowly finding out that my problems are from an incompetent

Get Price

Navien boilers | DIYnot Forums

Jun 06, 2021 · DIYnot Forums. Home Forums > General > General Discussion > Navien boilers. Discussion in 'General Discussion' started by transam, 5 Jun 2021. transam. Joined: 20 Nov 2009 Messages: 29,380 Thanks Received: 3,549 Location: Surrey Country: wrong forum oops Have a …

Get Price
Hey, let me help you!